Xiamen ZT Technology Co., Ltd.  Email: sales@zntar.com   zntarjason@gmai.com

DTP300 Electrical Fire Monitoring

DTP300 Electrical Fire Monitoring

Mainly used in the low-pressure three-phase four-wire system leakage protection and realize the main basic U, I, P, KWH and isoelectric parameter display; LCD display..........

More details


DTP300 Electrical Fire Monitoring


Mainly used in the low-pressure three-phase four-wire system leakage protection and realize the main basic U, I, P, KWH and isoelectric parameter display; LCD display, data turns display and designated show optional; With time memory function, alarm can record 50 fault happen type, time, departure time values, according to the fault record can analyse the reason of failures to provide basis for the elimination of failure.

 

Use range

1.Apply to all kinds of existing electrical equipment

2.High-rise buildings, fire hazard in places such as crowded conditions of electrical protection

3.Key fire-proof building electrical protection

4.Electrical parameters of time measurement

5.Electrical fire monitoring system

6.Suitable for 380V voltage grade palaces line protection


Professional design

Professional independent design, powerful, reveal the technical strength

Industrial parts, stable and reliable, the first-class quality

Through the national fire protection test

Series is complete multiple types can be chosen

Applicable to 0.4 KV electric voltage grade fire monitoring protection

Work into electricity switching power supply, work straight and wide range


DTP300 series product main function

LCD display, data turns display and specified display can be chosen

Has the leakage, temperature, pressure, undervoltage etc. Various protection function

To achieve the three-phase voltages, the power supply line, power, the three phasecurrent high-power electric parameters such as electric degrees, the measurement

Provide four lk switch input, programmable trigger events, can set with fire smoke sensors, remote signal connection, constitute fire linkage

Adopt fieldbus communication technology, PC management software can real-time monitoring each detector. Communication with RS485, this communication system reliability, expansibility, using international standards of Modbus - RTU agreement, can with all sorts of standard power monitoring software connected

With time memory function, alarm can record 50 fault happen type, time, triggering time values, according to the fault record can analyse the reason of failures to provide basis for the elimination of failure

Performance

Environmental conditions                                                         

Working temperature                                                                        The subject :-20℃~+50℃

Liquid crystal display (LCD) :                                                                   -10℃~50℃

Storage temperature                                                                                    -20℃~85℃

Relative humidity                                                                                       ≤95%

The altitude                                                                                                 ≤2000m

Degree of protection                                                                                IEC529IP52

Working power supply

Ac voltage                                                                                              85~265VAC

The power frequency                                                                                     45~65Hz

Dc voltage                                                                                     100~300VDC

Power consumption                                                                                 ≤2VA

Communication                                                                                       RS485

Interface                                                                                        Modbus-RTU

Communication protocol                                                                       2400~9600

Electromagnetic compatibility standards

Electrostatic  resistance test                                                                     IEC61000-4-2

  Radiation immunity test                                                                                IEC6100-4-3

Conduction rf interference test                                                             EN55022,ClassB

Transient pulse test                                                                     IEC61000-4-4,Level3

Surge immunity test                                                                        EC61000-4-5,Level3

Radio frequency radiation interference test                                           EN55022,ClassB

Rated current level (A)                                            16、25、32、40、50、63、80、100、

                                                                                       125、140、160、180、200、225、

                                                                                        250、315、400、630、800、1250

The rated voltage (V)                                 Three phase four wire, phase voltage AC220V

Residual current measuring range                                                                0~1000mA

Residual current setting value  l△            50~1000mAStep selection, each interval 50mA

Forecasting warning value l△no(mA)                                                  l△no=1/2 l△n

The action time (S)                                                    0.1~5adjustable ,interval 0.1S

Over-voltage action (V)                                               120~150%The rated voltage

Voltage under-voltage action (V)                                   60~80%The rated voltage

Temperature measurement :                                      10~150℃,action :55~140℃

 Overall dimensions                      DTP300:Length X width X height (mm)144X90X57

                                              DTP300B:Length X width X height (mm)96X96X55

                                                DTP300C:Length X width X height (mm)72X72X74

 

Selection Guide

Category

Single multi-function series

Multi-channel series

economy
Function
DTP300
DTP301
DTP302
DTP303
DTP310
DTP311
DTP300B
DTP300C
Real-time measuring value
Phase voltage
current
Residual current
Environment temperature
*
Total have power
Meritorious electric degrees

Protection

function

Leakage protection
Over-current protection
Temperature protection
*
*
Over/owe protection
Phase lack protection
Event record
Voice alarm
Self-check function

Expansion

function

Smoke detection
(S)
*2
*2
*2
Consumption linkage (F)
*1
*1
*1
*1
*1
*1
*1
*1
Alarm output (P)
*1
*1
*1
*1
*1
*1
*2
*1
Are dctection(A)
*
*
*
*
      —      —        —
Communication
RS485communication
Leakage circuit
 
1
1
1
1
4
8
12
1

“■” intrinsic function, "*" optional function, "-" no this function